● Transformers · substations · cables
Power, transformed. Delivered ready to energise.
Oil-immersed and dry-type transformers, power transformers up to 220 kV, prefabricated substations and the MV cables that connect them — engineered to IEC 60076, type-tested and shipped worldwide.
- Ratings
- 10 kVA – 40 MVA
- Voltage class
- up to 220 kV
- Cooling
- ONAN · ONAF · AN · AF
- Standards
- IEC 60076 · IEC 62271
01 — Products
Product range
Nine product lines, one quality standard — from a 10 kVA pole-mounted unit to a 40 MVA substation transformer.
-
01Oil-immersed transformersSealed S11 / S13 and amorphous-core oil transformers, 25 kVA to 2,500 kVA, up to 35 kV.
3 × Models

-
02Dry-type transformersCast-resin SCB10/11/13, amorphous SCBH15 and H-class SGB transformers for indoor, fire-safe sites.
4 × Models

-
03Power transformers3.15–40 MVA substation transformers, 35 kV to 220 kV, with on-load tap changers.
2 × Models

-
04Distribution transformersPole-mounted, pad-mounted and ground-mounted units for 6–35 kV networks.
1 × Models

-
05Box-type substationsEuropean-style prefabricated substations with HV, transformer and LV rooms in one enclosure.
1 × Models

-
06Compact transformersAmerican pad-mounted combined transformers and solar step-up box transformers.
2 × Models

-
07HV & LV switchgear12 kV metal-clad switchgear and low-voltage distribution boards — complete sets.
2 × Models

-
08Special transformersGrounding, solar step-up, single-phase and custom-engineered units.
1 × Models

-
09Power cablesXLPE medium-voltage cables 6/10 to 26/35 kV — made by Xinya.
1 × Models










Oil-immersed transformersFIG. 01
02 — Models
Featured transformers & substations
Data sheets, losses and type tests on every product page.
S11-M
Oil-immersed transformersS13 Oil-Immersed Distribution Transformer 10 kVSealed, low-loss, maintenance-free — the workhorse of every distribution network.
- Rated capacity
- 30–2,500 kVA
- Rated voltage
- 6–11 / 0.4 kV
- Standards
- IEC 60076
SBH15-M
Oil-immersed transformersSBH15 Amorphous-Alloy Oil-Immersed TransformerAbout 70% less no-load loss — energy savings every hour it is energised.
- Rated capacity
- 30–2,500 kVA
- Rated voltage
- 6–11 / 0.4 kV
- Standards
- −70% P0
XY-S13-33
Oil-immersed transformers33 kV Oil-Immersed Distribution TransformerBuilt for 11 kV and 33 kV networks in Africa, the Middle East and Asia.
- Rated capacity
- 25–2,500 kVA
- Rated voltage
- 11 / 33 kV
- Standards
- IEC 60076
SCB10
Dry-type transformersSCB10 / SCB11 / SCB13 Cast-Resin Dry-Type TransformerFire-safe, oil-free power for buildings, hospitals and factories.
- Rated capacity
- 30–2,500 kVA
- Rated voltage
- 6–11 / 0.4 kV
- Standards
- IEC 60076-11
XY-SZ11-35
Power transformers35 kV / 66 kV Power Transformer with OLTCSubstation and industrial power transformers from 3.15 to 20 MVA.
- Rated capacity
- 3.15–20 MVA
- Rated voltage
- 33–66 kV
- Standards
- IEC 60076
XY-SZ11-110
Power transformers110 / 132 / 220 kV Power TransformerHigh-voltage grid transformers up to 40 MVA, engineered per project.
- Rated capacity
- 16–40 MVA
- Rated voltage
- 110–220 kV
- Standards
- IEC 60076
YB-12/0.4
Box-type substationsYB European-Style Prefabricated SubstationHV switchgear, transformer and LV board in one weatherproof enclosure.
- Rated capacity
- 100–1,600 kVA
- Rated voltage
- 12 / 0.4 kV
- Standards
- IEC 62271-202
ZGS11-H
Compact transformersZGS11 American Pad-Mounted Compact TransformerTransformer, load switch and fuses in one sealed tank — four bolts to install.
- Rated capacity
- 30–1,600 kVA
- Rated voltage
- 10 / 0.4 kV
- Standards
- IP33
03 — Industries
From the grid to the last load — one supplier.
Pick a scenario and follow the power through each voltage level, with the matching equipment at every node.
Generator step-up and primary substation transformers carry power to 10–35 kV feeders, where sealed S13 or amorphous distribution transformers serve towns, villages and businesses.
MV / LV cabling: XLPE Medium-Voltage Power Cable YJV / YJV2204 — Sizing tool
What rating do you need? Find out in 20 seconds.
Enter the maximum demand of your site. We calculate the apparent power, pick the next standard rating and suggest the matching equipment — then an engineer confirms it.
Recommended rating
1,250kVA
Transformer loading: —
Full-load current
Suggested equipment
Indicative: kVA = kW ÷ PF × (1 + growth), sized for ≤ 90% loading. Final rating, impedance and losses are confirmed by our engineers.
05 — Manufacturing
Built on real production lines — not a trading desk.
Our transformers are built on real production lines: foil and wire winding, vacuum resin casting, oil-filling lines and a full routine-test bay.






06 — Quality & certification
Every unit tested before it ships.
Routine tests on 100% of units, type tests by a CNAS-accredited national laboratory, and a management system certified to ISO 9001, ISO 14001 and ISO 45001.
| 01 | Winding resistance & voltage ratio | ✓ 100% |
|---|---|---|
| 02 | Vector group & polarity | ✓ 100% |
| 03 | No-load loss & current | ✓ 100% |
| 04 | Load loss & impedance | ✓ 100% |
| 05 | Applied & induced voltage withstand | ✓ 100% |
| 06 | Partial discharge (dry type) | ✓ 100% |
| 07 | Oil dielectric strength & tightness (oil type) | ✓ 100% |
- IEC 60076-1/-2/-3/-5/-11
- IEC 62271-200/-202
- GB 1094
- GB/T 10228
- GB/T 6451
- GB/T 17467
- IEC 60502-2
07 — Industries
Industries we power
Five sectors, each with a proven equipment line-up.
01
Utilities & power grid
Power and distribution transformers for networks.
- Up to 40 MVA / 220 kV
- OLTC or off-circuit tap changers
- Rural electrification units
02
Industry & mining
Reliable supply for plants, mines and process lines.
- Dry type F/H class
- Unit substations to 2,500 kVA
- MV & LV switchgear
03
Solar, wind & storage
Step-up transformers for renewable plants.
- 0.8 / 35 kV step-up units
- Double-split LV windings
- Grid-connection to 220 kV
04
Commercial & real estate
Compact substations for buildings and campuses.
- Prefabricated 100–1,600 kVA
- Low noise down to 45 dB
- Fire-safe dry type indoors
05
Infrastructure & data centres
Transformers for rail, airports and data halls.
- Amorphous low-loss cores
- Redundant N+1 layouts
- IP23 enclosures & monitoring

08 — Power cables
The transformer is only as good as the cable feeding it.
Xinya started as a power cable manufacturer. Every transformer and substation we supply can ship with the MV and LV cables specified for it — sized, terminated and tested.
- MV power cable
XLPE-insulated copper cable 6/10 to 26/35 kV to IEC 60502-2, armoured or unarmoured, from our own lines.
- Terminations & joints
Heat-shrink or cold-shrink terminations matched to bushings, elbow connectors and switchgear.
- One set of test records
Cable routine tests delivered together with the transformer test report for your inspector.
- One shipment
Transformers, substations and cable drums consolidated in one container booking.
09 — Get a quote
What you actually get
Every inquiry is answered by an engineer, not a sales script.
Send load and voltages. We return rating, impedance, guaranteed losses and an outline drawing.
Get a quoteAttend the factory acceptance test or watch it live on video, with the reports for your serial numbers.
Get a quoteType-test reports, routine-test certificates, drawings and manuals ready for your utility, consultant and customs.
Get a quoteMV and LV cables cut to length and terminated to your drawing — shipped with the transformer.
Get a quote10
From inquiry to energisation
A clear path, with an engineer — not a salesperson — at every step.
- STEP 01Inquiry
Send load, voltages, site and standard. Reply within one working day.
- STEP 02Engineering
Rating, impedance, losses and outline drawing for your approval.
- STEP 03Production
Core, winding, casting or oil filling with progress photos.
- STEP 04Testing
Routine tests, optional witness test or video FAT.
- STEP 05Delivery
Seaworthy packing, documents and installation guidance.
11
Questions buyers ask
Short answers from our engineers. Ask anything else in the inquiry form.
Oil-immersed or dry-type: which transformer should I choose?
Choose oil-immersed for outdoor yards and the lowest cost per kVA; choose cast-resin dry type for indoor rooms, high-rise buildings, hospitals and anywhere fire rules restrict oil.
How do I size a distribution transformer?
Divide the maximum demand in kW by the power factor to get kVA, add margin for future growth, then pick the next standard rating so the transformer runs below about 90% load. Our sizing tool does this in seconds.
Which standards do your transformers meet?
IEC 60076 (oil-immersed), IEC 60076-11 (dry type), IEC 62271-202 (prefabricated substations) and the Chinese GB 1094 / GB/T 10228 / GB/T 6451 series. Other voltages, frequencies and standards are engineered to order.
What is the difference between S11, S13 and amorphous transformers?
They are energy-efficiency levels. S13 has about 20–30% lower no-load loss than S11, and amorphous-alloy cores cut no-load loss by about 70% versus S11 — the best choice where transformers run lightly loaded.
What is the typical lead time?
Standard distribution transformers and substations usually ship within a few weeks of drawing approval; power transformers take longer. We confirm a firm date with every quotation.
Can I inspect or witness tests before shipment?
Yes. You can attend factory acceptance tests in person or by live video, or appoint a third-party inspector. Test reports for your serial numbers are supplied with the shipment.
12 — News
Transformer & grid insights
Market moves, standards and buying guides — updated daily.
Your Trusted China Transformer Manufacturer for Overseas ProjectsChina transformer manufacturer for overseas projects, Professional EV Charging Solutions, export quality transformer, international power transformer supplier, EPC transformer manufacturer
Global Standards, Local Expertise: A China Transformer Factory IEC IEEE CompliantChina transformer factory IEC IEEE compliant, Professional EV Charging Solutions, IEC 60076 transformer, IEEE C57 standard, compliant power transformer manufacturer
Safety & Compliance: Verify Our China Transformer Supplier UL File NumberChina transformer supplier UL file number, Professional EV Charging Solutions, UL listed transformers, dry-type transformer certification, compliant transformer manufacturer● RFQ
Planning a transformer or substation project?
Tell us the load, voltage levels and site. You get a selection, outline drawing and quotation within one working day.








